61
10. Specifications
Specifications
Model
FP102
FP302
FP312
FP412
Safety Device
Self-diagnosis Functions (Temp. Sensor Failure Detection, TRIAC
Short Circuit, Heater Line Disconnection,
Main Relay Failure Detection, Automatic Overheat Prevention
)
Key Lock Function, Independent Overheat Prevention Device, ELB
S
tan
da
rd
Internal dimensions (mm)
※
2
W100
×
D150
×
H100
W200
×
D250
×
H150
W300
×
D250×H150
External dimensions (mm)
※
2
W376
×
D404
×
H515
W446
×
D504
×
H565
W506
×
D504×H625
Internal capacity (L)
1.5
7.5
11.3
Power supply (50/60Hz)
Single phase AC115V
Single phase AC220V
Rated current
10A(15A)
21.5A(30A)
13A(15A)
18A(20A)
Weight
Approx. 29kg
Approx. 43kg
Approx. 51kg
A
c
c
es
s
ori
es
Exhaust port cap
1
Fuse
1
Furnace floor plate
1
Instruction manual
1 copy
V-type quick manual
1 copy
Warranty card
1 copy
Articles
※
The length of the power cord outside the unit is about 2
m
.
※
1 Performances have been measured at the rated source voltage,
single phase 115V or 220V
±
5%, room temperature of 23
℃±
5
℃
, humidity of 65%RH
±
20%, voltage of 86kPa
~
106kPa, and
at no-load.
※
2 Measurement conditions: FP102 is at 3 points in the bath,
FP302,312, and 412 are compliant with JIS.
※
3 Protrusions are excluded.
Summary of Contents for FP102
Page 67: ...64 12 Wiring diagram FP102 Wiring diagram Dotted line means optional parts ...
Page 68: ...65 12 Wiring diagram FP302 Wiring diagram Dotted line means optional parts ...
Page 69: ...66 12 Wiring diagram FP312 Wiring diagram Dotted line means optional parts ...
Page 70: ...67 12 Wiring diagram FP412 Wiring diagram Dotted line means optional parts ...