background image

I

USER'S INFORMATION
MANUAL

G

lfHCllHC't'

••,..a

CUH'HlO

ama

(~

~

"'''Jl,

I.:lA;r;~'"

1509001

Certified Quality

Management System

MODELS:

33" Multi-position

Gas Furnaces

(Manufactured Housing or Modular Home Applications)

I_~~--~-~~~~~-~~-~~~~~

TABLE OF CONTENTS

SAFETY

1

Removing Filters For Manufactured (Mobile) Home

INSTRUCTIONS FOR EXAMINING THE

And Modular Home Installations Without A Return

FURNACE INSTALLATION

2

Air Duct System And Plenum

4

START-UP AND SHUTDOWN INSTRUCTIONS

2

BLOWER CARE

.4

HOW YOUR GAS FURNACE WORKS

3

MOTOR LUBRICATION

5

OPERATING INSTRUCTIONS

3

SERVICE INFORMATION

5

TO TURN OFF THE APPLIANCE

3

TROUBLESHOOTING

PROBLEMS

5

FURNACE MAINTENANCE - USER INFORMATION

4

FURNACE CONTROL DIAGNOSTICS

5

EXTERNAL AIR FILTERS

4

FURNACE MAINTENANCE - DEALERICONTACTOR

5

How to Clean your Filter

4

REPLACEMENT PARTS LIST

5

Removing Filters For Manufactured (Mobile) Home And Modular

WIRING DIAGRAM

5

Home Installations Using A Return Air Duct System And Plenum

4

LIMITED WARRANTY

6

CONTACT INFORMATION FOR USA

CONTACT INFORMATION FOR CANADA

.

Contact us by mail:

.

Manufacturer:

.

Go to website at

www.york.com

click on "contact", then click on

DISTRIBUTED BY:

Johnson

Controls

Unitary Products

"contact form" and follow the instructions.

StyleCrest

.

Contact us by mail:

801 W. 37th Street

Johnson

Controls

Unitary Products

Building

#7

Consumer

Relations

Wichita, Ks 67219

5005 York Drive

Norman, OK 73069

We recommend that the user read all sections of this

manual and keep the manual for future reference.

rAWARNINGl

FIRE OR EXPLOSION HAZARD • Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.

Do not store or use gasoline

or other flammable

vapors

and

liquids

in the vicinity

of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone (includ-
ing cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation

and service must be performed

by a qualified

installer, service agency or the gas supplier.

SECTION I: SAFETY

I

A

I

This is a safety alert symbol. When you see this symbol on

~_

!abels or in manuals, be alert to the potential for personal

mjury,

Understand and pay particular attention to the signal words DANGER,

WARNING, or CAUTION.

DANGER indicates an imminently

hazardous situation, which, if not

avoided, will result in death or serious

injurv.

WARNING

indicates a potentially

hazardous situation, which, if not

avoided, could result in death or serious

injurv.

CAUTION

indicates

a potentially

hazardous

situation,

which, if not

avoided may result

in minor

or moderate

injurv.

It is also used to

alert against unsafe practices and hazards involving only property dam-

age.

1.

The furnace area must be kept clear and free of combustible mate-

rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials

may be combustible.

The furnace must be

kept free and clear of insulating materials. The furnace area must

be examined when installed in an attic or other insulated space or

when insulation is added to be sure that the insulation material has

been kept away from the furnace.

3.

The furnace needs air for combustion in order to operate properly

and safely. Do not block or obstruct air openings on the furnace,

air openings to the area where the furnace is installed, or spaces

around the furnace.

4.

Follow the instructions

exactly as shown on the OPERATING

INSTRUCTION

LABEL on the furnace or the "START-UP AND

SHUTDOWN INSTRUCTIONS" section of this manual when light-

ing the furnace or turning the furnace off.

5.

Should the gas supply fail to shut off or if overheating occurs, shut

off the gas valve to the furnace before shutting off the electrical

supply.

6.

Do not use this furnace if any part has been under water. A flood-

damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency

should be contacted to inspect the furnace and replace all gas

controls, control system parts, electrical parts that have been wet

or the furnace if deemed necessary.

420706-UUM-A-1008

Summary of Contents for 33"

Page 1: ...ou cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SECTION I SAFETY IA IThis is a safety alert symbol When you see this symbol on _ abels or in manuals be alert to the potential for personal mjury Understand and pay particular attention to the signal words DANGER WARNING or CAUTION DANGER...

Page 2: ... pipe making sure it is firmly in place that it slopes slightly upward and is physically sound without holes and all of the connections are secure 3 Examine return connections For Modular Homes a If the fumace has a return air duct examine the return air duct connections to make sure they are physically sound sealed to the furnace casing and the ducts terminate out side the space containing the fu...

Page 3: ...cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above for your protection 2 Set the thermostat to the lowest setting in the heat mode 3 Turn off all electric power to the appliance 4 Remove furnace burner access panel door 5 Move gas control switch to the OFF positio...

Page 4: ...n in Figure 5 To check clean or replace the air filters you should 1 Follow the instructions to turn off the appliance before servicing 2 Filters that are installed in the return air plenum above the blower assembly and are located in an V frame assembly that supports the filters as shown in Figure 5 3 To remove the filters you must remove the screws that are secur ing the access panels on the ret...

Page 5: ...e code For example six on flashes equals a number 6 fault code All flash code sequences are broken by a 2 sec ond off period SLOW GREEN FLASH Normal operation DOUBLE AMBER FLASH Normal heating operation Modulating Fur nace Models Only SLOW AMBER FLASH Normal operation with call for heat RAPID RED FLASHES There is a problem with the operation of this furnace Contact your local dealer contractor or ...

Page 6: ...leaning replacement of filters or any other routine maintenance as set out in the User s Information Maintenance and Service Manual 11 Replacement or cleaning of nozzles or orifices 12 Fuses either internal or external to the product 13 Excessive fuel or electricity consumption THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABIL IT...

Reviews: