8 - 63
–
+
ELEC
IMMOBILIZER SYSTEM
2. No malfunction code is displayed on the
LCD display of the meter assembly.
YES
NO
1. Voltage
• Connect the pocket tester (DC 20 V) to the
meter assembly coupler as shown.
LCD display
Positive tester probe
→
red/white
1
or red/green
2
Negative tester probe
→
black/white
3
• Turn the main switch to “ON”.
• Measure the voltage (DC 12 V) at the
meter assembly coupler (wire harness
side).
• Is the voltage within specification?
Replace the meter
assembly.
The wiring circuit
from the main switch
to the meter assem-
bly coupler is faulty
and must be
repaired.