44
IGNITION SYSTEM
ELEC
CHARGE COIL
1.
Measure:
Charge coil resistance
Out of specification
Replace.
Charge coil resistance:
Brown / White
(Br/ W) – Black (B)
497.7
608.3
Ω
at 20
C
(68
F)
PULSER COIL
1.
Measure:
Pulser coil resistance
Out of specification
Replace.
Pulser coil resistance:
White / Red (W / R) – Black (B)
12.6
15,4
Ω
at 20
C
(68
F)
THERMO SWITCH
1.
Measure
Thermo switch continuity
Out of specification
Replace.
Thermo switch continuity
temperature:
Pink (P) – Black (B)
a
66
74
C
(100.4
125.6
F)
b
57
43
C (93.2
78.8
F)
1 Discontinuity
A Temperature
2 Continuity
B Time
3 Discontinuity
Measurement steps:
Suspend thermostat in a vessel.
Place known reliable thermometer in water.
Heat water slowly.
Observe thermometer, while stirring water
continually.