5-18
ENG
OIL PUMP, CRANKCASE AND CRANKSHAFT
INSPECTION
1. Measure:
•
Runout
Use the V-blocks and a dial gauge.
Out of specification
→
Replace or repair the
crankshaft.
Dial gauge:
90890-03097, YU-03097
Maximum runout:
C
1
: 0.03 mm (0.0012 in)
C
2
~ C
5
: 0.04 mm (0.0016 in)
C
6
: 0.03 mm (0.0012 in)
a
90 mm (3.54 in)
b
85 mm (3.35 in)
2. Measure:
•
Small end free play
a
Use the dial gauge.
Out of specification
→
Replace the defective
parts.
Small end free play:
a
0.8 ~ 1.0 mm (0.03 ~ 0.04 in)
•
Big end side clearance
b
Use the thickness gauge.
Out of specification
→
Replace the defective
parts.
Big end side clearance:
b
0.25 ~ 0.75 mm (0.01 ~ 0.03 in)
3. Inspect:
•
Crankshaft bearing
1
Pitting/damage
→
Replace.
•
Stopper ring
2
Bends/damage
→
Replace.
•
Crankshaft oil seals
3
•
Impeller drive gear teeth
4
Wear/damage
→
Replace.
CAUTION:
Lubricate the bearings immediately after examin-
ing them in order to prevent rust.
SCH5400
SCH5410
SCH5420
Summary of Contents for VT700F
Page 2: ......
Page 8: ......
Page 118: ...2 42 INSP ADJ CARBURETOR TUNING Guide for carburetion SCH2815 ...
Page 155: ...INSP ADJ ...
Page 445: ...8 19 ELEC ...
Page 523: ...9 22 SPEC ...
Page 545: ...9 22 SPEC ...
Page 567: ...9 22 SPEC ...
Page 568: ...SPEC 9 23 CABLE ROUTING SCH9010 ...
Page 570: ...SPEC 9 25 CABLE ROUTING SCH9010 ...
Page 572: ...SPEC 9 27 CABLE ROUTING SCH9020 ...
Page 574: ...SPEC 9 29 CABLE ROUTING SCH9030 ...
Page 576: ...SPEC 9 31 CABLE ROUTING SCH9030 ...
Page 578: ...SPEC 9 33 CABLE ROUTING SCH9040 ...
Page 580: ...SPEC 9 35 CABLE ROUTING SCH9050 ...
Page 582: ...SPEC 9 37 CABLE ROUTING SCH9050 ...
Page 584: ...SPEC 9 39 CABLE ROUTING SCH9060 ...
Page 588: ......