When Charging with ESC3 (Li-ion 00 Lithium Ion Battery)
Problem
Charger LED
Indication
Battery LED
Indication
Check Point
What to Do
Will not charge
Off
Off
Is the power cord connected?
Connect the power cord to a power
source.
Off
Off
Will another battery accept a charge?
If it can be charged, the charger is nor-
mal. Use a rechargeable battery.
If it cannot be charged, the charger may
be faulty. Contact your dealer.
Flashing green
(5times per second) Off
The charger has remained in standby
mode for a long time and has stopped
charging the battery.
Wait for the battery temparature to drop
and try to charge the battery again.
Flashing red (5times
per second)
Off
Are a Ni-MH battery and a Li-ion
battery connected at the same time?
If both are connected at the same time,
disconnect one of them.
Can another battery be charged?
If it can be charged, the charger is nor-
mal. Use a rechargeable battery.
If it cannot be charged, the charger may
be faulty. Contact your dealer.
Flashing red
(once per second)
Off
Unplug the power plug, stop charging the
battery and contact your dealer.
Lit red
Off
Unplug the power plug, stop charging the
battery and contact your dealer.
Prolonged charge
standby
Flashing green
(once per second)
Residual capacity
indicator lamps are
lit
Is the battery temperature appropri-
ate?
The charger is in standby mode. This
does not indicate a malfunction.
Wait until the battery reaches an appro-
priate temperature.
Flashing green
(once per second)
Residual capacity
indicator lamps are
lit
Is the ambient temperature appropri-
ate?
Charge the battery in an environment with
an appropriate temperature (cool in the
summer and warm in the winter).
Stops charging
halfway
Off
Residual capacity
indicator lamps are
lighted only halfway
Is the temperature of the battery
high?
After the battery has cooled down, try
charging again.
After charging is
completed, all of
the lamps are not
lit
Off
Residual capacity
indicator lamps are
lighted only halfway
Check the number of times or days
you have used the battery.
Has the battery deteriorated?
After approximately 300 charge/discharge
cycles, the battery capacity will decrease
to approximately 60% of that of a new
battery.
The charger emits
a sound
Lamp display varies
with the conditions.
Residual capacity
indicator lamps are
lit
Is the sound unusual?
Unplug the power plug, stop charging the
battery and contact your dealer.
The charger gets
unusually hot
Lamp display varies
with the conditions
Residual capacity
indicator lamps are
lit
While the charger is charging the bat-
tery, it is normal for the unit to heat up
to some degree (about 104–140 °F,
about 40–60 °C). If the charger gets
too hot, though, it may be malfunc-
tioning.
Unplug the power plug, stop charging the
battery and contact your dealer.
The charger emits
an odor
Lamp display varies
with the conditions
Residual capacity
indicator lamps are
lit
Does this occur immediately after you
start using the charger?
The charger may emit an odor immedi-
ately after it is put to use, but the odor will
disappear eventually.
If the odor persists, unplug the power
plug, stop charging the battery and con-
tact your dealer.
Summary of Contents for NAVIGO
Page 28: ...1 22 1 6 Warning Label Location Diagram Power Unit and Controller NAVIGO 16 FRONT BACK ...
Page 29: ...1 23 NAVIGO 24 FRONT BACK ...
Page 30: ...1 24 Lithium Ion Battery Nickel Metal Hydride Battery Back side ...
Page 31: ...1 25 Charger for Lithium Ion and Nickel Metal Hydride Battery ESC3 ...