ELEC
8-9
6D45F11
Electrical systems
Digital circuit tester: 90890-03174
Peak voltage adapter B:
90890-03172
Charge coil peak voltage:
Brown (Br) – Blue (L)
r/min
Unloaded
Loaded
Cranking
1,500
3,500
DC V
175
170
180
180
Charge coil resistance
(use as reference):
Brown (Br) – Blue (L)
272.0 – 408.0
Ω
at 20°C (68°F)
L
Br
6D480160
B
W/G
6D480140
Pulser coil resistance
(use as reference):
White/green (W/G) – Black (B)
234.0 – 348.0
Ω
at 20°C (68°F)
Checking the charge coil
1.
Measure the charge coil output peak volt-
age. If the measurement is below specifi-
cation, check the leads, and measure the
charge coil resistance. Replace if neces-
sary.
L
L
Br
Br
6D480150
6D45F11-08 03.10.10 9:50 Page 10