33
11
First segment pulse (low bit)
1
0
-9999
~
+9999
○
12
First segment pulse (high bit)
1
0
-9999
~
+9999
○
13
First segment speed
0.1rpm
0
0
~
50000
○
14
First segment adjustment time
1ms
0
0
~
65535
○
15
First segment command filter time
0.1ms
0
0
~
65535
○
P2-16~P2-90 are 2~16 segments parameter setting.
94
.
xx□x
Find the original point
0: invalid
1: valid
-
0
0~1
●
94.
xxx□
The signal quantity pass the Z phase
signal at the direction of leaving the
limit switch
A
2
1
~
F
(
Hex
)
●
95
The speed of closing the proximity
switch
0.1rpm
600
0~50000
○
96
The speed of leaving the proximity
switch
0.1rpm
100
0~50000
○
4. P3: speed control
(
0300
~
03FF
)
P3-
Name
Unit
Default
Range
Effective
00
Analog value of rated speed
0.01V
1000
150
~
3000
○
01
Internal setting speed 1
rpm
100
-5000
~
+5000
√
02
Internal setting speed 2
rpm
200
-5000
~
+5000
√
03
Internal setting speed 3
rpm
300
-5000
~
+5000
√
04
JOG speed
rpm
100
0
~
1000
√
05
Soft start acceleration time
1ms
0
0
~
65535
○
06
Soft start deceleration time
1ms
0
0
~
65535
○
07
Speed command filter time
0.01ms
0
0
~
65535
○
08
Speed feedback filter time
0.01ms
20
0
~
65535
○