6
2
)
Installation Site
Indoor
,
free of corrosive or explosive gases.
Well-ventilated and free of dust and moisture.
Ambient temperature of 0° to 50°C.
Relative humidity (r.h.) of 20 to 90% with no condensation.
Accessible for inspection and cleaning.
3
)
Concentricity
Please use coupling when connecting to machine; keep the shaft center of servo motor
and machine at the same line. It should be accord to the following diagram when installing
the servo motor.
Caution
:
(
1
)
If the concentricity is not enough, it will cause the vibration and bearing damage.
(
2
)
When installing the coupler, prevent direct impact to the shaft. This can damage
the encoder mounted on the shaft end at the opposite side of the load.
4
)
Orientation
MS series servomotors can be installed either horizontally or vertically.
5
)
Handling Oil and Water
Install a protective cover over the
servomotor if it is used in a location that is
subject to water or oil mist. Also use a
servomotor with an oil seal when needed to
Measure it at 4 places of the circle, the difference should be
below 0.03mm. (Rotate with the shaft coupler)
Measure it at 4 places of the circle, the difference should be
below 0.03mm. (Rotate with the shaft coupler)
Through part of the shaft