40
not connected
power-off, or replace the
damaged encoder
E-014
Encoder ABZ
wire break
Encoder wiring error,
encoder broken, encoder is
not connected
Check the wiring of encoder,
and re-connect the encoder after
power-off, or replace the
damaged encoder
E-015
Speed changes
too fast
(encoder
feedback error)
The encoder wiring is error,
or the encoder has
interference
Check the wiring of encoder, or
add shield layer for the encoder
wire
E-016
Overload
Run overload for long time
Reduce the overload running
time, change a motor with larger
rated power
E-017
Power off when
running
Bus voltage is too low when
running
Re-power on after the bus
voltage is normal
E-018
Erase parameter
error
Voltage is too low when
power on, cannot erase the
parameter
Check the power supply and
re-power on
E-031
Motor code
error
Motor code cannot match to
drive type
Set the motor code in F2-00
again
E-032
Initialization
error
System chip is damaged
Contact XINJE or an authorized
distributor
►►
Debug steps
b)
Please check the products before power on, make sure the devices are not
significant damage.
c)
Connect the cables correctly. Connect U, V, W one-to-one, don’t cross them.
d)
Power on, panel display: bb;