Maintenance
Safety Devices Inspection
3
3-20
HDdoc012020
Maintenance
2. Inspection of the control circuits with the E-STOP button pressed
Start the engine;
Turn the tensioner handle to engage the blade;
Press the E-STOP button located on the left side of the control box. Engine should be stopped..
With E-STOP button pressed try to move the saw head up and down (using switch and setwork
buttons) and forward/backward using power feed switch. Both systems shouldn’t start.
With E-STOP button pressed try to start the debarker blade motor and move the debarker arm
in and out. Debarker shoudn’t work.
With E-STOP button pressed try to move the blade guide arm in and out. Blade guide arm
shoudn’t work.
With E-STOP button pressed try to control the board return arm. Board return arm shoudn’t
work.
20_121d
Emergency
Stop Button
Engine Key
Switch
Saw Head
Forward
Saw Head
Reverse
Saw Head
Up
Saw Head
Down
Debarker
Arm In/Out
Debarker
Motor On/Off
Blade Guide
Arm In/Out