Maintenance
Vertical Mast Rails
3
3-4
HDdoc012020
Maintenance
3.5
Vertical Mast Rails
Clean and lubricate the vertical mast rails every 50 hours of operation. Clean with solvent and remove any rust
with a light-grade sand paper or emery cloth. Lubricate the mast with motor oil or automatic transmission fluid
(ATF).
CAUTION!
Never use grease on the mast rails as it will collect sawdust.
3.6
Drum Switches
Lubricate the up/down and power feed drum switch contacts inside the control panel every fifty hours of opera-
tion. Use only contact grease supplied by Wood-Mizer. Remove the control panel cover. Use a cotton swab to
apply grease to the switch contact ends.
WARNING!
Drum switch grease contains Petroleum Hydrocarbon Lubricant.
Eye and skin irritant. If introduced into eyes, flush with water for at least 15
minutes. If film or irritation persists, seek medical attention. Wash skin with
soap and water. If ingested, do not induce vomiting - contact a physician.
KEEP OUT OF THE REACH OF CHILDREN.
See Figure 3-3.
FIG. 3-3
Loosen thumb-
screw to open
housing lid
Remove track
wiper, clean
and lubricate
Adjust track
scrapers (2)
Clean sawdust
from upper cam
housing
Carriage track
50