Manual-overview of system
15.Error code
Code
display
error
Remarks
00
01
Preset maintenance interval
expired
Levelling not correct and inspection run not
possible when maintenance period is invalid.
02
Door lock OFF
03
UP limit Sw. OFF
Uppermost end switch reached
04
Dn limit Sw. OFF
Lowermost end switch reached
05
Can't open door
Door could not be opened.
8 trials failed in normal mode.
06
Can't close door!Tuer Zu
Fehler
Door could not be closed.
8 trials to close fails in normal mode
free
08
CANbus Err
CAN-bus connection to car
controller panel disturbed
No connection to car controller panel or final
resistance not active.
09
Inverter Err
Error on inverter
Input X11 depicts error at inverter
10
Up Sw. 1 Err
End switch up 1 defectous
11
Down Sw. 1 Err
End switch 1 down defectous
12
Up Sw. 2 Err
End switch up 2 defectous
13
Down Sw. 2 Err
End switch2 down defectous
14
Up Sw. 3 Err
End switch up 3 defectous
15
Down Sw. 3 Err
End switch 3 down defectous
16
Up Sw. 4 Err
End switch up 4 defectous
17
Down Sw. 4 Err
End switch 4 down defectous
18
free
19
Door limit Err
20
Sliding Protect
Sliding protect has triggered
Elevator takes longer then presetted time in
F62 without changing levelling signals
21
Motoroverheat
Motor is overheated
PTC Input longer than 2 sec.
→
active!.
22
Enc. Wrong Dir.
Real direction of rotation isn't the
same with the controlled one
Encoder signal in wrong direction in normal
modem with more than 0,15m/s.
23
Enc. Overspeed
Elevator runs to fast
Multistep mode: after 1,5sek delay the speed
is still over 0,2m/s.
Analogue Mode: rated-speed is 25% über
target-speed.
Real speed is 8% higher than nomninal speed.
Landing speed is over limit landing speed.
24
Enc. Lowspeed
Elevator runs to slow
Multistep: after 3s still below 50mm/s.
Analogue-Mode: elevator slower than 50% of
Seite 69