Manual – overview of system
Correct signal Inputs at AS.T030 (LEDs)
On the mainboard the signalinputs are depicted via LEDs. Those signal are transfered serial from the POS
sensor to the drive monitor who directs the signals parallelto AS.T030 the sheme shows:
-elevator in the lowest leveling position within KU
-elevator in leveling position outside KU/KO
-elevator in highest leveling position within KO
elevator in the lowest leveling position within KU
Input designation
X4
X5
X6
X7
X18
X19
LED at AS.T030
●
● ●
In control parametrised as
*
*
-
-
-
-
elevator in leveling position outside KU/KO
Input designation
X4
X5
X6
X7
X18
X19
LED at AS.T030
● ● ● ●
In control parametrised as
*
*
*
*
-
-
levator in highest leveling position within KO
Input designation
X4
X5
X6
X7
X18
X19
LED at AS.T030
● ● ●
In control parametrised as
*
*
*
*
-
-
X18: correction up (Only relevant for short floor)
X19: correction down (Only relevant for short floor )
X4: correction up
X5:correction down
X6: Relevelling UP
X7: Relevelling DOWN
X18 (short north magnet) und X19 (short southmagnet) arm additional retardation switches and are only needed
for short floor shorter than 1,6 m within the correction switches KU or KO. Normally they are not needed and
they are not connected therefore.
The named signal has to be at AS.T029 , otherwise a learning movement is not possible.
Seite 28