Manual-overview of system
7.AS380 Main board AS.T029
Assignment of input/ Output:
The Inputs/ Outouts can be assigned -within defined limits-freely.
Sheme below shows how they are assigned in the very often cases.
Individual signals could be assigned in special cases odifferent.
This will be underligned in the circuit sheme. Thus the circuit map
is
is applicable!
AS.T029 connections:
Terminal
Name
Description
Function
Advise
JP1
1
Nx1
Neutral wire main contactor from supply line
110V/
230VAC-
scan
optocoupler.
VDE EN81
2
X20
Scan emergencysection of safety loop
3
X21
Scan end of safety loop
4
X22
Scan revolving door contacts
5
Nx2
Neutral wire to the main contactors
JP2
1
Y0
Open brake and keep open
Outputs main
contactors
conform
EN81
2
Y1
Open brake (drops down to reduce brake tension)
3
Y2
Motor contactors
4
Y0-2
Common contact for output relais Y0-Y2
JP3
1
Y3
Output for K14 (complete bypass)
2
Y4
Output evacuation end
3
Y3-4
common Y3 and Y4
4
Y5
Output fire/ firemanoperation active
5
Y5c
Common Y5
6
Y6
free
7
Y6c
common Y6