Manual – overview of system
Insp.Option include all parameters which are necessary for the start-up in the
inspection mode
S Curve is needed for the use of the analogue Output of the converter control.
Lvl.Mic.Adj. Enables the correction of each levelling at every floor.
Normally not necessary because the floors are calibrated during the learning
movement.
Multi Speed includes all parameter, which are necessary for the run of the
converter in multistep-mode ( parallel control).
Door Control enables the parametrisation for door control.
Flr.Disp. Leads to the list of the floor idicators.
For every floor you can set individually the displayed letter combination (for
Step SM04 displays). The announcement for the landings on each floor is
fixed by this dsiplay code.
The Display codes are stated in a chart in the appendix.
Service Floor determines the enabled floors. Also the floors which are only
enabled by key-switch are determinded.
Block Floor permits blocking of a floor via time or key switch..
Comp. Stop (enforced stop) defines stops where the elevator is brought to an
enforced stop when passing by. Make sense in some cases for Hotels.
Heavy Traf. Permits the function „emptying/ filling building“.
So the haul capacity of a office building could be increased
In Test Run the parameter F34 can be set for a number of runs, which the
elevator should make without any command for testing purpose.
Para. Setup is the access to the complete parameterlist.
Reset brings all parameters to factory setting. Has only be made if absolutely
neccessary! Before the Reset a number has to be entered to avoid an accidantly
reset.
Attention! After the entry of the number the reset is made without any further
inquiry!
Set F146 imperativly on 0 !