![WITTUR iAStar AS380 Manual Download Page 57](http://html1.mh-extra.com/html/wittur/iastar-as380/iastar-as380_manual_990317057.webp)
Manual – overview of system
No.
name
description
Factory
setup
scope
F126 free
F127 free
F128
Front and rear
door
operate mode
Door mode at two doors
0
:
selective door control active
1
:
both doors controlled together
0
~
3
F129
Relevelling with
door
open and/or pre-
open
door Enable
r
e-levelling with open door/
prerunning door opening (requires
security circuit):
0
:
no security circuit
1
:
prerunning door
2
:
re-levelling with open door
3
:
both
0
~
7
F130
Holding door-
opening/closing
torque.
Door triggering (keep close/open):
0
:
no close/open-keeping
Bit 1
:
door open-keeping (in case
cabin door is pulled by the shaft
door)
Bit 2
:
door close-keeping (in case
the bolt opens without keep-close-
moment)
Bit 3
:
keep close during the
journey (in case tie bolt bangs
against the locking bolt)
Bit 4
:
no door-close-end-switch
Bit 5
:
AT120 door control
Bit 6
:
revolving door
0
0
~
7
F131 Block floor no
blockable floors
0: not active
1
~
64: number of the floor which
have to be blocked.
0
~
64
F132
block floor start
time
Time at which the floor <F131>
should be closed: e.g. 730 for
7:30 o
́
clock
0
~
65535
F133
block floor end
time
Time at which the floor <F131>
should be released. e.g.: 930 for
9:30 o`clock
0
~
65535
F134 free
F135 free
F136 free
F137 NS-SW floor16
Defines floors, which can be
blocked with a key-switch:
Bit mask 1-16
0
~
65535
F138 NS-SW floor32
Bitmask 17-32
0
~
65535
F139 NS-SW floo48
Bitmask 33-48
0
~
65535
F140 free
F141
Motor contactor off
delay
Caster time of engine contactor :
approval off=>contactor off
0.5s
0.5~10.00
Seite 60