Manual-overview of system
different functions (Func.Select)
Time Setup: setting of then realtime-clock. Is needed for the fault-record and
the time dependant enabled floors. And also for the function „filling/ emptying
building“.
Door Teach: detect via opening and cloasing the function of the door-
endswitches.
Shaft Teach: has to made imperativly before going to normal mode ( after
mounting or changing door position)
Door, bus, shaft copying and cabinlight has to work correctly.
After activating of shaft teaching the elevator runs in the lowest stop and starts
with the learning movement.
After finish the elevator can go into normal mode. If an error occurs the
learning movement is stopped and an error messages appears..
Reset Para.F: Rest on factory setting!!!
Reset Errco.: deleting of fault record!
Error Reset: Reset after Lift Error (fatal fault) eg. Run monitor, contactor
monitoring, Bakemonitoring etc..
Relogin: Logout and relogin.
Normaly after 10 min. without input automatically logout!
Chg.Password: changing Password
Attention! Don't forget password-could only be resetted in factory!
Seite 11