Manual – overview of system
The doors stay closed to avoid hazard if the test fails.
Functional check-Version A with trundle (via check menu):
These procedure is only designated for cable elevator with gearless drives.( synchronous motors) and
simulates the case of a noncontrolled trundle.
The paces for checking of UCM Function are integrated in the software of the AS380 control means the
test-relay K.A3T and K14 is directly triggered.
•
Elevator is ready for operation in a middle floor.
•
Doors are closed.
•
Now activate in the menu Test the UCM Test A
•
via the Testrelay K.A3T the door circuit is opened to check when door is closed. K14 is avtivated
to close the bridging.
•
Now K2 (Motorcontactor) and K8 (Brakecontactor) is actuated.
•
The elevator trundles up ( cabin empty) or down ( cabin loaded).
•
After leaving the doorzone the elevator has to stop!
•
The elevator has to come to a stop within the limit values.
•
The passed distance is indicated on the display or can be measured after the opening from the
shaftdoor.
•
If the elevator trundles away more than 2m the test has to be aborted.
Functional-check Version B with inverter (via check-menu):
these procedure is designated for cable elevator with gear drives.( asynchronous motors) and simulates the
movement with defined acceleration (caused by the inverter)
The paces for checking of UCM Function are integrated in the software of the AS380 control means the
test-relay K.A3T and K14 is directly triggered.
•
Elevator is ready for operation in a middle floor.
•
Doors are closed.
•
Now activate in the menu Test the UCM Test B
•
via the Testrelay K.A3T the door circuit is opened to check when door is closed. K14 is avtivated
to close the bridging.
•
Now a normal run Up ( empty cabin) or down (loaded cabin) acuated.
•
After leaving the doorzone the elevator has to stop!.
•
The elevator has to come to a stop within the limit values.
•
The passed distance is indicated on the display or can be measured after the opening from the
shaftdoor.
•
If the elevator trundles away more than 2m the test has to be aborted.
•
With the below shown calculations the maximal breaking distances can be calculated. Basis is the
set acceleration.