Operating manual
cyber
®
dynamic system
en-30
Doc. no.: 5022-D056658
Revision: 01
6.4.8 X5: Power supply
Figure
Pin no. Signal name
Function
Input / output
1
DC Bus+
Intermediate circuit
v
Input
2
DC Bus-/GND Intermediate circuit
voltage - / earth
Input
3
LOGIC
Logic supply
Input
4
STO_VCC
Safe torque off input
Input
5
STO_GND
STO ground
reference
Input
FE
FE
Functional earth
Functional earth
Plug type on drive system: M12, 6-pin, male, M-power
6.5 Fuses
The power supplies are to be secured with the fuses specified in the table:
Fuses
Logic supply (F2)
X5 (pin 3)
Fuse or similar with max. 4 AT
Power supply (F1)
X5 (pin 1)
Fuse or similar with max. 10 AT
Further requirements regarding NRTL compliance are listed in chapter 2.1.2
”.
Circuit breaker hardware to protect the drive system is not required as the drive system
is protected from overloading by an I²t function in the software.
Connection
Feature
Unit
Minimum
value
Nominal
value
Maximum
value
DC Bus
Current
A DC
0
4
(3,3 A +22%)
14
(11,5 A +22%)
Voltage
V DC
12
48
60
VDC
12
24
48
60
LOGIC, without brake, output
stage inactive
mA DC
220
110
60
50
LOGIC, without brake,
output stage aktiv
mA DC
230
115
65
55
STO, output stage inactive
mA DC
14
8
6
5
STO, output stage active
mA DC
20
11
9
7