Operating manual
cyber
®
dynamic system
en-40
Doc. no.: 5022-D056658
Revision: 01
9 Malfunctions
Changed operational behavior can be an indication of existing
damage to the drive system or can cause damage to the
drive system.
Do not put the drive system back into operation until the cause of the
malfunction has been rectified.
Fault
Possible cause
Remedy
Drive system does
not start
Connected incorrectly
Check the connection using the list
of signals.
Contact pin of the plug is bent
Check the connections.
Parameter set does not
correspond to the drive
system
Check the motor data record in the
power electronics.
Increased
operating
temperature
Drive system is heavily soiled
Clean the outside of the
drive system.
Ambient temperature too high
/ air pressure too low due to
altitude
Ensure adequate cooling.
Drive system becomes
very hot
Consult our Customer Service
department.
Threaded spindle heavily
worn
Consult our Customer Service
department.
Increased
operating noises
Damaged bearings
Consult our Customer Service
department.
Threaded spindle or gearbox
damage
Sporadic failure
Cable break
Consult our Customer Service
department.
Table 15: Malfunctions
The contact information of our Customer Service department can be found at the beginning
of this manual (inside cover page). Always state the serial number (SN) when doing so.