7.4 Operation
Due to oxygen in the air, UV rays, and cable movements, the
bearing grease and the insulation materials age.
Consult our Sales department in case of excessive wear.
Circumferential radial forces on the shaft are not permitted.
If this requirement cannot be fulfilled, please contact our sales department.
Always state the serial number (SN) when doing so.
Due to various components and seals, a new drive can be
noticeably more difficult to move. To ensure optimum grease
distribution and running-in of the moving components, the drive
should run in as follows:
15 min at slow speed load-free (approx. 10 % vmax)
10 min at medium speed load-free (approx. 30 % vmax)
5 min with increased speed load-free (approx. 60 % vmax)
If a stop occurs as a result of the switch-off due to excessive heating, a pause between
the individual stroke cycles is recommended.
Due to the stroke movement of the piston rod, a certain amount of
lubricant leakage is possible with the CDSL version.
7.5 Startup software
For parameterization and startup of the drive, the startup software Motion GUI 2 is available
as well as an interactive, html-based guide.
The startup software Motion GUI 2 is used to change and save the operating parameters
of the drive system. The integrated drive system can be put into operation with the help of
software.
In the html-based help, all parameters and the function of the drive system are described.
Nonconforming parameterization can cause uncontrolled
movements. For this reason, never change parameters whose
meaning you do not completely understand.