7.6 Displays on the drive system
Three multicolor LEDs (DS, MS, NS) in the colors green, yellow and red are available on the
drive system for status and fault messages.
LED
EtherCAT
Ethernet/IP
PROFINET
DS
Drive Status
Drive Status
Drive Status
MS
RUN-LED (EtherCAT
Drive Statemachine)
Module State
System
Failure
NS
ERR-LED (EtherCAT
Error State)
Fieldbus State
Bus Failure
DS
Drive Status
Drive Status
Drive Status
Table 7: Displays on the drive system
7.6.1 LED codes DS
LED DS is the drive LED which is identical for all bus system types.
Status
LED
LED DS
Meaning
Off
Drive amplifier has no power supply or
drive is defective
Flash:
Green
Drive amplifier is in functional state but
output stage is disabled
Flash:
Red
Drive amplifier is in fault state and output
stage is disabled
Flash:
Yellow
Drive amplifier is in warning state and
output stage is disabled
Flash:
Yellow,
Green
Drive amplifier is in warning state and
output stage is enabled
Constant:
Green
Drive amplifier is in functional state and
output stage is enabled
Flash:
Red,
Green
Drive amplifier is in Firmware Update state
Table 8: LED codes DS