2 Safety
This operating manual, especially the safety instructions, and the rules and regulations valid
for the operating site, must be observed by all persons working with the drive system.
In addition to the safety instructions in this manual, also observe any legal and otherwise
applicable environmental and accident prevention rules and regulations (e.g. personal safety
equipment).
2.1 Approvals
2.1.1 CE conformity
The drive system was tested in authorized testing laboratories in accordance with the
requirements of this documentation. Deviations and nonconformity with requirements in this
documentation mean that the drive system may not fulfill statutory requirements under certain
circumstances.
The drive system is in conformity with the following directives:
-
EC directive (2009/125/EC)
-
Machinery Directive (2006/42/EC)
-
Electromagnetic Compatibility (EMC) (2014/30/EU)
-
RoHS Directive (2011/65/EU)
Startup is prohibited within the scope of the EC directives until it has been determined that the
machine/system in which this drive system is installed corresponds to the regulations within these
directives.
In terms of interference immunity, the drive system fulfills the requirement for the category
“second environment” (industrial environment).
In the area of interference emission, the drive system fulfills the requirements for category C3.
In a residential environment, the drive system may cause radio
interference, necessitating interference suppression measures such
as an external EMC filter.
2.1.2 Conformity with TÜV NRTL
This drive system is approved under the TÜV reference number 028-713170081-000 and falls
under the category Power Conversion Equipment.
Explanations:
NRTL:
Approval according to standards of the United States in accordance with UL 61800-5-1
Approval according to national Canadian standards in accordance with C22.2 No. 274-13,
1st edition
NRTL Markings:
Maximum Altitude: 2000 m
Maximum Surrounding Air Temperature: 55 °C
These devices are intended to be used in a pollution degree 2 environment
Use minimum 90 °C copper wire
Integral Solid State short circuit Protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical Code
and any additional local codes