D. LED Indicators
WRU Deployed
Table D–6 WRU LED Indications, Deployed WRU, Geophone Down Tilt
LED Indicators
Summary
Description
Undeployed
Dead Batteries
Sleeping
If no LEDs are on (lit up) before tilting the
WRU, it can be one of the following scenarios:
•
WRU undeployed
•
Batteries dead
•
WRU Sleeping
•
WRU Awake, but unformed
When you do a tilt test (geophone down) on a
WRU with no LEDs on, the following may
occur:
•
An Undeployed WRU deploys and begins
the self tests
•
A WRU with dead batteries will continue
to display no lit LEDs
•
A Sleeping WRU goes back to the
deployed, unformed state and displays
the battery status and any self-tests that
failed during deployment (BAT, THD, GEO,
GPS, or RAD).
•
A WRU in the Awake unformed state
displays the battery status and any self-
tests that failed during deployment (BAT,
THD, GEO,GPS, or RAD).
NOTE: Battery state is shown in the
RT System 2 user interface tables.
For example, the Ground Equipment
Table.
Battery A in use
A Flashing:
•
Battery A in use
•
WRU formed or Armed
NOTE: Only when GPS position occurs at the
same time the battery status is
displayed.
Battery B in use
B Flashing:
•
Battery B in use
•
WRU formed or Armed
NOTE: Only when no self-test failures. Re-
acquire GPS position occurs at the
same time the battery status is
displayed.