Tab 6-17
SYSTEM STATUS
Item
Function
Effect
001
START AST button
Starts the engine in astern direction (for reversible engine)
002
STOP button
Stops the engine
003
START AHD button
Starts the engine in ahead direction
004
CTRL. TR. button
Sends a signal for a control transfer to this LDU-20
005
INDEX button
Opens the INDEX page
006
Refresh button
Updates the module status list
007
Status indications for each module Shows either:
•
Initialization:
Hardware module has been reset and
bootloader has started the application
•
Bootloader, staying in bootloader:
Different version of
application/configuration/DSP is found, SW download is
necessary to synchronize the module with the rest of the
system
•
Pre-operational, synchronization:
Module is booting up
and waits for synchronization
•
Pre-operational, ready:
Module is booting up, every-
thing set-up successfully and is ready to enter Opera-
tional state
•
Operational:
Module operates correctly, System soft-
ware and application initialized successfully
•
None:
Module is set to OFF or disconnected from the
CAN bus
•
Stopped:
Module is not configured correctly, system ini-
tialization has failed, state is transitioned from pre-oper-
ational state
The usual working cycle is as follows:
•
Reset
•
Initialization
•
Pre-operational --> Stopped --> Reset
•
Operational --> Stopped --> Reset
008
Download button
Does a software download on the selected modules
X52
AA00-9606-34AAA-043B-A
Operation Manual
LDU-20 page - SYSTEM STATUS
Winterthur Gas & Diesel Ltd.
- 255 -
Issue 002 2018-11