4
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
75
Installation, Operating and
Maintenance Instructions
The external control unit controls and monitors access to the door.
• Operation is ensured via transponders that work contactless.
• Hold a taught transponder chip into the proximity (0 - 5 cm) of the antenna.
• Once the transponder chip is close enough to where it can read the
information, communication is established contactfree.
• The transponder data are transmitted to the control unit via the antenna.
• An acoustic door signal will acknowledge the data transfer.
• The control checks whether this transponder chip is authorized to access
and okays / denies access.
4.2 blueMotion with transponder
• After the enable time has elapsed, another transponder can be recognized
and evaluated.
• If a transponder chip is unknown to the control, access will be denied.
Action
Acoustic signal
Result
Door with transponder
"Open"
n n
short, short
authorized
4.2.1 Operation
Action
Acoustic signal
Result
Door with transponder
"Open"
n nnnnn
short, long
not authorized
• When switching from night to day mode, 1 x must be unlocked electrically
or mechanically, then the day mode is activated and the hooks are or remain
retracted.
• When switching from day to night mode will be locked immediately.