12 V
24 V = Delivery Status
CAUTION!
blueMotion must be
operated with 24 V DC.
Notice:
Check the proper position of the jumper before
starting operation!
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
52
Installation, Operating and
Maintenance Instructions
No. Terminals wireless receiver
1
"Break contact (NC)", is not necessary
2
"Contact (C)", from the wireless receiver to the "Open" button of the
external control unit (terminal 11)
3
"Make contact (NO)", from the wireless receiver to the "Open" button
of the external control unit (terminal 12)
4
"12 V DC resp. 24 V DC", power supply, e.g. from Winkhaus power
supply unit (connect with white wire of the cable transition)
5
"0 V DC", power supply, e.g. from Winkhaus power supply unit
(connect with brown wire of the cable transition)
6
"Auxiliary antenna / ANT" (not required)
7
"Auxiliary antenna / GND" (not required)
Figure 3.6.1-2: Adjustment of the jumper for voltage selection
• The default setting of the jumper is 24 V.
• The wireless receiver can be adjusted from 24 V to 12 V via the jumper.