3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
34
Installation, Operating and
Maintenance Instructions
Frame part 1
(Figure 1):
• Drill a hole with a Ø 8 mm for cable through the door frame
• Pass the cable through the door frame (including cable reserves in frame!)
• Fasten the frame part 1
with the fitting screw
Ø 3 x 20 mm
Frame part 2
(Figure 2):
• Drill a hole with a Ø 13 mm for cable / plug through the door frame
• Pass the cable with plug for frame power supply through the door frame
(including cable reserves in frame!) use T-Cover strip KÜ-T1 RT R8 einsetzen
• Fasten the frame part 2
with the fitting screw
Ø 3 x 20 mm
Installation sequence
Sash part
Frame part 1
Frame part 2
T-Cover strip
KÜ-T1 RT R8
Cover plate
(F16 = L 126 mm R8;
F20 = L 130 mm R10;
F24 = L 134 mm square)
Screw M3 x 12
(includet in delivery
from cover plate)
Fitting screw
(includet in delivery
from cable transition
sash part T-KÜ-T1 FT)
Sash part
with cover plate
(Figure 1):
• Mill slotted hole max. 95 mm and approx. 50 mm deep
Sash part
without cover plate (Figure 3):
• Drill a hole 2 x Ø 13 mm resp. oblong hole through the euro grove (approx.
245 mm vertical under the frame part drill hole of Ø 8 mm, depends on the
profile/hinge rotation point) and for screw
pre-drill (Ø 2,5 mm)
Figure 3.3.1-1: T-KÜ-T1 FT with cover plate and frame part 1
Di
st
an
ce
a
p
p
ro
x.
2
4
5
U
nd
er
pr
e-
te
ns
ion
!