Notice:
If the external control unit and buttons are placed in the
switch box at the same time, they must have a depth of
65 mm!
CAUTION!
When connecting on intercom system, make sure
that the intercom system output is designed as a potential-free
contact! No voltage liable to cause interference must reach the
external control unit from the intercom!
The cable length between the buttons and the control unit may
at the most amount to 100 m (2 x 0,8 mm²).
Notice:
If day / night service switch and wireless receiver are
accommodated in the switch box at the same time, they must
have a depth of 65 mm!
If several opening options are used at the same time, they must
be switched parallel to the "Open" button (e.g. button from
inside, wireless remote and intercom).
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
46
Installation, Operating and
Maintenance Instructions
• The external control unit should preferably be housed in a 65 mm deep
switch box.
• In the very same switch box, you can install the button to unlock the door
from the inside.
• In another switch box you can mount the changeover switch for day / night
service (on customer request).
• If you have chosen to use the Winkhaus wireless receiver can this install it in
the same switch box (see installing the wireless receiver).
• Before the door is operated electrically, first test mechanically for ease of
movement!