Notice:
These switch boxes should be mounted on the interior,
in close proximity to the entryway door!
CAUTION!
Please note that the relay output with max.
30 W at 30 V max. 1 A may be charged.
This is not on output for the alarm system, because the
mechanical locking modus is not monitored, this must be done
by a deadbolt switch contact (RSK)!
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
45
Installation, Operating and
Maintenance Instructions
Installation of external control unit with acoustic signal indicating
free / open / accessible
The buzzer indicates that
the door is open, until it is
closed again.
The circuit is made via
the output swing door
drive (Terminals 6 - 8).
Figure 3.4-5: Installation external control unit with acoustic signal
(insert any resistor)
signal
transmitter
e.g. Piezo
Installation sequence
• Prior to installing the blueMotion unit, connect the sash cable of the cable
transition "T-KÜ-T1 FT ..." or "T-Connection cable 6 m ..." to the motor
housing.
• Run the cable to the switch boxes.