7
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
90
Installation, Operating and
Maintenance Instructions
Rated output E.R.P.:
50 - 100 µW
Range in an unobstructed area: max. 30 m
Dimensions:
61 x 36 x 16 mm
Wireless receiver (separate)
Type of receiver:
Superheterodyne
Modulation: AM / ASK
Frequency:
433.92 MHz
Frequency of the local oscillator: 6.6128 MHz
Intermediate frequency:
10.7 MHz
Sensitivity (to receive signal): -115 dB
Input impedance:
50 Ohm
Max. memory capacity:
85 codes for the remote control
Power supply unit:
12 / 24 V AC / DC
Closed-circuit current:
15 mA
On-load current:
33 / 48 mA
Number of relays:
(1 NO-NC)
Power:
24 W
Dimensions:
80 x 80 x 50 mm
7.6 Cable transition T-KÜ-T1 FT
General Specifications
Measurements:
Overall length approx. 260 mm
Cross section of wires:
6 x 0.25 mm²
Max. voltage:
48 V DC
Protection classification:
IP 54
Max. switching current:
2 A per connection line / wire
Screw fixing:
3 piece 3 x 20 mm, 1 piece 2.9 x 32 mm
(included in set sash part)
Cable transition T-KÜ-T1 FT sash part
Sash part:
• T-KÜ-T1 FT 2 M with 2 m cable + plug for motor
housing
• T-KÜ-T1 FT 3,5 M with 3.5 m cable + plug for
motor housing