Notice:
The remaining airgap between the lock and the
magnetic bush has to amount to 4 ± 2 mm.
If you are using stainless door furniture, use the "EST" magnetic
bush. It is identified by a black magnet.
Notice:
After the sensor has triggered, 1 second will pass by
until the power locking mechanism starts.
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
33
Installation, Operating and
Maintenance Instructions
Figure 3.2-2: Magnetic bush adjustments
You can adjust the mag-
net with a screw-driver
by ± 3 mm on two planes:
After installing the door
you will have to adjust the
magnet in such a way as
to ensure that the sensor
reliably triggers once the
latch snaps into place.
3.3 Cable transition
3.3.1 Cable transition T-KÜ-T1 FT (sash- + frame part)
Recommendation:
It is recommended always that the cover plate
(depends
on the faceplate and the material type of timber, PVCu / plastic or aluminum)
conceals the routing for the required cable reserves to prevent possible cable
damage.
Recommendation:
For hollow chamber / cable reserve in timber front doors, mill
out pocket of approx. 50 mm x 95 mm.