3.9 Function switch day / n ight / reset
• Top (direction sun) = day function
• Center position = night function (default setting)
• Low (direction moon) = button for reset / reset the error counter
Push the button in lower position and hold it for min. 6 second
= Signal sound out of the motor housing (1 x circa 1 second)
= Error counter is reseted
Button springs independently back in the center position / night function
3.10 Control of additional functions
A)
Additional applications (only ekey home integra 2)
• The control of a additional application (e.g. garage door, alarm system) takes
place via the second relay of the integra 2.
• To this is a second cable transition needed.
(e.g. T-KÜ-T1 FT 2M, Art.-No. 5040501)
• This one to cut to length and connect the two red wires (potential-free
contact) on the 8-pole plug of the control unit professionally (see figure
3.8.2-5 ).
• The two needed wires of the cable transition are free selectable.
B)
Swing door opener (ekey home integra 1 resp. 2 or IDENCOM BioKey
INSIDE)
• To this is a second cable transition needed.
(e.g. T-KÜ-T1 FT 2M, Art.-No. 5040501)
• Open the housing EV-G and remove the rubber bush, out of the cable gland.
• The cable transition to cut to length and guide the cable through the cable
entry into the housing EV-G.
• The two needed wires of the cable transition are free selectable.
• According which swing door opener is used, put the cable on 6 / 7
(break / normally closed contact) or 7 / 8 (make / normally open contact) of
the external control unit.
• Screw together the housing again.