Notice:
When using the transponder set blueMotion
"T-C TRANSPONDER SET T01" no direct control of
swing door drive is possible. Therefor the transponder set
blueMatic EAV (see Figure 3.7-2) must be used.
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
55
Installation, Operating and
Maintenance Instructions
• Relay becomes briefly active after being
activated per remote control and after about
1 sec. it will be deactivated automatically.
JP1 = OFF
K4 Impuls
Figure 3.6.2-3: Setting the K4 relay
3.7 Connection of swing door drive
The application of the blueMotion lock is generally suitable for swing door dri-
ves.
The lock was specifically tested with swing door drives:
• GEZE TSA 160,
• GEZE Slimdrive EMD
• DORMA ED 200 (control B)
• DORMA CD 80
Wiring plans available on request from Winkhaus and the swing door drive
manufacturers.