CAUTION!
The drillings must be burr-free. The spring must be
kept under a slight pre-tension even with the door being closed
(approx. 10 mm).
CAUTION!
Release the second retaining screw
(e.g. during
the installation of the door frame into the reveal) when unhinge
the door sash!
Insulate the wires not used!
CAUTION!
Provide cable reserve of
about 3 - 5 cm for the spring tension
behind the sash part
of the cable
transition!
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
35
Installation, Operating and
Maintenance Instructions
• Attach necessary drillings (Ø 13 mm) in the
sash (e.g. in the glazing chamber)
• Pass the cable with the plug for the motor
through the door sash
• Insert the end of the spring into the sash part
into the drilling / routing into the door
sash / cover plate are.
• And/or alternatively to the cover plate
with screw M3 x 12 mm
fasten the sash
part
with fitting screw Ø 3 x 20 mm in the
fitting groove.
• Install the cable for example within the
glazing chamber towards the motor housing;
install the rest of the cable for example within
the hollow section.
Figure 3.3.1-2: Detail
frame part 2
Figure 3.3.1-3: Detail
T-KÜ-T1 FT without
cover plate
• Complete the plug-in connection after
putting the door on its hinges
• Fix the sash part
with the fitting screw
Ø 3 x 20 mm (Figure 1)