1.0  SCOPE 

 
This instruction sheet covers methods required to move, adjust and operate the MFE locking kit with 
the Multi-Function Fiber Enclosure. 
 
 

2.0  PRODUCT DESCRIPTION 

 
This retrofitable Locking Kit provides additional security to the Multi-function Enclosure. 
Allows the enclosure to be secured and reduce unauthorized entry. 
 

3.0  PREPARATION:  

 

  Before beginning assembly of the product, make sure all parts are present. If any parts are 

missing or damaged, do not attempt to assemble the product.  
 

  Make sure the product and accessory parts (listed below)

 

are present, and not damaged. 

 

 

CHART FOR ACCESSORIES: 

 

 

 
 
 
 
 
 
 

DESCRIPTON 

QTY 

PORT ID LABEL MFE LOCKING KIT

 

SCREW M4X8 CSK POZI BZP

 

HEX NUT M4x3mm SS A2

 

WASHER FLAT M4X0.5 STEEL BZP 

LOCK KEY 

Summary of Contents for MFE LOCKING KIT

Page 1: ... covers methods required to move adjust and operate the MFE locking kit with the Multi Function Fiber Enclosure 2 0 PRODUCT DESCRIPTION This retrofitable Locking Kit provides additional security to the Multi function Enclosure Allows the enclosure to be secured and reduce unauthorized entry 3 0 PREPARATION Before beginning assembly of the product make sure all parts are present If any parts are mi...

Page 2: ...ion as shown in Fig 1 Make sure that adapter plate is fixed to the enclosure base before locking kit is fixed to it On the base of the Locking Kit are 3 holes and 2 studs to match 3 pem nuts and 2 slots of enclosure On the base of the enclosure 3 Pem nuts and 2 slots are available to mount the Locking Kit In both the parts 2 callout slots are available for wall mounting application shown in Fig 2 ...

Page 3: ... and match the holes with the pem nuts in such a way that it is flush as shown in Fig 4 Fig 3 Fig 4 Ensure the two fixed studs are positioned at slots extreme edge and all 3 holes are aligned to pem nut holes as shown fig 5 Fig 5 Fix the screws from the bottom of the Locking Kit base to pem nuts on enclosure base Use the appropriate tool to tighten the screws to the pem nuts and fully tighten the ...

Page 4: ... below when enclosure base is wall mounted to work on fiber routing termination and any other installation work and bring back the lever to original position by slightly lifting the enclosure top cover up WARNING Dust caps should be left intact on all adapters not in use Never look into an open adapter as laser light may be present and is invisible Serious eye damage is possible Metal Lever should...

Reviews: