molex MFE LOCKING KIT Installation Instructions Download Page 4

 

EC/ECM NO: 176403 

SAP  NO : 187000495 

Doc No: 187000495   Doc part: AS 

REV-A 

MPN/FMT-042 (2016/07/01 REV-00).                                                                                                                                                                                                                                             SHEET No. 4 of 4                                                    

 

  Once the Locking Kit is ready for use, all connections can be made from front and the inside 

of the enclosure. 

  Port ID label can be affixed to the door plate for port ID identification, as shown in Fig 7. 

  Use the provided Cam lock to secure the locking kit by rotating 90 degree direction, using 

keys. 

 

        

 

           (Fig.7) 

 
 

 

 

  Use the available riveted metal levers (with free rotational movement) rotating 90 degrees 

(Clockwise /Counter clockwise) direction to stop/secure the enclosure top cover (as shown 
below), when enclosure base is wall mounted, to work on fiber routing, termination and any 
other installation work, and bring back the lever to original position by slightly lifting the 
enclosure top cover up. 

 
 
 

                                                    

 

                                                                                                                                                             

 

 

 

WARNING:

 

Dust caps should be left intact on all adapters not in use. 

Never look into an open adapter as laser light may be present 

and is invisible. Serious eye damage is possible. 

Metal Lever should be rotated 
Clockwise/Counter clockwise, 
direction up to the stopper, to 
prevent the top cover from sliding 
down as shown.  

Use 2mm thick washers 
M10X20mm (not provided) at the 
base, when the Locking Kit is 
mounted to the wall along with 
enclosure, for better flatness at 
base. 

 locking kit. 

Rotate the key counter clockwise 
to lock and clockwise to unlock 

Top cover  

Affix the Port ID label to door plate 

Summary of Contents for MFE LOCKING KIT

Page 1: ... covers methods required to move adjust and operate the MFE locking kit with the Multi Function Fiber Enclosure 2 0 PRODUCT DESCRIPTION This retrofitable Locking Kit provides additional security to the Multi function Enclosure Allows the enclosure to be secured and reduce unauthorized entry 3 0 PREPARATION Before beginning assembly of the product make sure all parts are present If any parts are mi...

Page 2: ...ion as shown in Fig 1 Make sure that adapter plate is fixed to the enclosure base before locking kit is fixed to it On the base of the Locking Kit are 3 holes and 2 studs to match 3 pem nuts and 2 slots of enclosure On the base of the enclosure 3 Pem nuts and 2 slots are available to mount the Locking Kit In both the parts 2 callout slots are available for wall mounting application shown in Fig 2 ...

Page 3: ... and match the holes with the pem nuts in such a way that it is flush as shown in Fig 4 Fig 3 Fig 4 Ensure the two fixed studs are positioned at slots extreme edge and all 3 holes are aligned to pem nut holes as shown fig 5 Fig 5 Fix the screws from the bottom of the Locking Kit base to pem nuts on enclosure base Use the appropriate tool to tighten the screws to the pem nuts and fully tighten the ...

Page 4: ... below when enclosure base is wall mounted to work on fiber routing termination and any other installation work and bring back the lever to original position by slightly lifting the enclosure top cover up WARNING Dust caps should be left intact on all adapters not in use Never look into an open adapter as laser light may be present and is invisible Serious eye damage is possible Metal Lever should...

Reviews: