4-8
n
Vesta Gas and Electric Slide-In Ranges
DIAGNOSTICS & TROUBLESHOOTING
For Service Technician Use Only
FOR SERVICE TECHNICIAN’S USE ONLY
12
F9E0 Miswired
Product is miswired.
Anytime a miswired
product condition is
detected.
1.
Unplug range or disconnect power.
2.
Check wires and connectors between main control (P6) and
power cord.
3.
Check that the L1-L2-N wiring (pigtail) from the power outlet is
correctly connected to the range terminal block.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power.
6.
Start a self-clean cycle and observe for 1 minute to ensure that
operation is normal. Enter the diagnostic mode to view the
“Faults” screen. Press START TIME or DELAY START to clear
each Fault code(s).
CODE WHAT IS IT?
WHEN CAN IT OCCUR? RECOMMENDED CORRECTIVE ACTION PROCEDURE
13
Relay Logic
Main Oven
Legend
NOTE:
Pre A/B represents two stages of preheat. SS represents steady state
(after reaching preheat temperature).
Modes
Relays
Bake Broil Convect
Element
Convect
Fan
Bake (Rapid Preheat) Preheat
©
©
©
©
Bake (Rapid Preheat) Steady State
©
©
O
X
Bake (Standard Preheat) Preheat
©
©
©
X
Bake (Standard Preheat) Steady State
©
©
O
X
Broil Preheat
O
X
O
O
Broil Steady State
O
©
O
O
Keep Warm Preheat
©
©
O
O
Keep Warm Steady State
©
©
O
O
Self Clean
©
©
O
O
Bread Proof Preheat
©
©
O
O
Bread Proof Steady State
©
O
O
O
Cvt Bake Preheat (True Convect)
©
©
©
X
Cvt Bake Steady State (True Convect)
©
©
©
X
Cvt Broil Preheat (True Convect)
O
©
O
X
Cvt Broil Steady State (True Convect)
O
©
O
X
Cvt Roast Preheat (True Convect)
©
©
©
X
Cvt Roast Steady State (True Convect)
©
O
©
X
Cvt Bake Preheat (Fan Convect)
©
©
O
X
Modes
Relays
Bake Broil Convect
Element
Convect
Fan
Cvt Bake Steady State (Fan Convect)
©
©
O
X
Cvt Broil Preheat (Fan Convect)
O
©
O
X
Cvt Broil Steady State (Fan Convect)
O
©
O
X
Cvt Roast Preheat (Fan Convect)
©
©
O
X
Cvt Roast Steady State (Fan Convect)
©
O
O
X
On
Off
On or Off
X
O
©