DIAGNOSTICS & TROUBLESHOOTING
Vesta Gas and Electric Slide-In Range
n
4-5
For Service Technician Use Only
FOR SERVICE TECHNICIAN’S USE ONLY
6
Failure/Error Display Code Repair Procedures
CODE WHAT IS IT?
WHEN CAN IT OCCUR? RECOMMENDED CORRECTIVE ACTION PROCEDURE
Feature Not Available
This message will scroll across the display when a fault
is detected while you are programming a cook cycle.
Anytime.
1.
Cycle power to the range (wait 30 seconds before reapplying
power). If the error message reappears, go to Step 2. If the error
message does not reappear after 120 seconds, go to Step 6.
2.
Unplug range or disconnect power.
3.
Replace main control board.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power.
6.
Verify operation is normal. Enter the diagnostic mode to view the
“Faults” screen. Press START TIME or DELAY START to clear
each Fault code(s).
F1E0 EEPROM Communication Error
The main control is locked up due to an unexpected
communication event. This is often corrected by cycling
power.
Immediately after the
main control sees an
unexpected event.
1.
Cycle power to the range (wait 30 seconds before reapplying
power). If the error code reappears, go to Step 2. If the error
code does not reappear after 120 seconds, go to Step 6.
2.
Unplug range or disconnect power.
3.
Replace main control board.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power.
6.
Verify operation is normal. Enter the diagnostic mode to view the
“Faults” screen. Press START TIME or DELAY START to clear
each Fault code(s).
7
F2E0 Keypad Disconnected
The main control no longer sees the keypad.
Within 60 seconds of the
keypad being
disconnected.
1.
Unplug range or disconnect power.
2.
Inspect keypad connection to main control (connector P12). If
connection loose/unplugged, reconnect.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power. Allow 60 seconds for main
control to identify keypad. If error code reappears, go to Step 5.
If the error code does not reappear, go to Step 9.
5.
Unplug range or disconnect power. Inspect keypad connector,
keypad cable, and main control connector P12 for signs of
damage (cracked locking tab, bent pins, etc.). If damage found,
go to Step 8.
6.
Replace all parts and panels before operating.
7.
Plug in range or reconnect power. Allow 60 seconds for main
control to identify keypad. If error code reappears, go to Step 8.
If the error code does not reappear, go to Step 9.
8.
Replace components in the following order of likelihood of failure
a.
Keypad cable
b.
Keypad
c.
Main control
9.
Replace all parts and panels before operating.
10.
Plug in range or reconnect power
11.
Verify operation is normal. Enter the diagnostic mode to view the
“Faults” screen. Press START TIME or DELAY START to clear
each Fault code(s).
F2E1 Stuck Keypad
A keypad has been pressed for an extended period of
time. This could be the result of the user pressing a
keypad for too long.
Within 120 seconds of a
keypad being pressed
and held.
1.
Disconnect power to the range (wait 30 seconds before
reapplying power). If the error code reappears, go to Step 2. If
the error code does not reappear after 120 seconds, go to Step
6.
2.
Unplug range or disconnect power.
3.
Replace the keypad.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power
6.
Verify operation is normal. Enter the diagnostic mode to view the
“Faults” screen. Press START TIME or DELAY START to clear
each Fault code(s).
CODE WHAT IS IT?
WHEN CAN IT OCCUR? RECOMMENDED CORRECTIVE ACTION PROCEDURE