4-12
n
Vesta Gas and Electric Slide-In Ranges
DIAGNOSTICS & TROUBLESHOOTING
For Service Technician Use Only
FOR SERVICE TECHNICIAN’S USE ONLY
20
F-47
Power supply from Induction
Power Control (IPC) to User
Interface is missing or WIDE
communication error between
UI and Induction Power Control
(IPC) or an open fuse on the
filter board
Type 2
1.
Unplug range or disconnect power.
2.
Check that the cables between the User Interface and the Induction Power Control (IPC)
are not damaged and are firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check that it is working. If it is not working,
disconnect power and replace the cables between the User Interface and the Induction
Power Control (IPC).
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power and check that it is working. If it is not working, go to
Step 7.
7.
Unplug range or disconnect power.
8.
Check the continuity of the fuses on the EMI board. If either of the fuses is blown, replace
with a new one.
9.
Replace all parts and panels before operating.
10.
Plug in range or reconnect power and check that it is working. If it is not working, go to
Step 11.
11.
Unplug range or disconnect power.
12.
Change the Induction Power System (IPS).
13.
Replace all parts and panels before operating.
14.
Plug in range or reconnect power. Check that it is working. If it is not working, go to
Step 15.
15.
Unplug range or disconnect power.
16.
Change the User Interface.
17.
Replace all parts and panels before operating.
18.
Plug in range or reconnect power.
F-56
Wrong or invalid configuration
Type 3
1.
Unplug range or disconnect power.
2.
Replace the User Interface.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
Service Code
Shown on Display
Failure Description
Type of
Failure
Repair Suggestions
21
F-58
Wrong or invalid configuration
Type 2
1.
Unplug range or disconnect power.
2.
Replace the Induction Power System (IPS).
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
F-60
UI does not work
Type 3
1.
Unplug range or disconnect power.
2.
Check for loose connections between the User Interface and both Induction Power
Controls (IPCs).
3.
Replace the User Interface.
4.
Replace all parts and panels before operating.
5.
Reconnect the power.
C-81, C-82
Over temperature
Type 2
Not enough ventilation: Check the installation according to the Installation Instructions. In
particular, check the blower intakes.
C-83
Temperature sensor stuck
Type 2
1.
Unplug range or disconnect power.
2.
Check to see if the temperature sensor that is causing the failure is firmly plugged into the
proper connector.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check to see if the coil is working. If it is not
working, unplug range or disconnect power and replace the coil that is causing the failure
with a new coil.
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power and check to see if the coil is fixed. If it is not working,
disconnect power and replace the Induction Power System (IPS).
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
Service Code
Shown on Display
Failure Description
Type of
Failure
Repair Suggestions