COMPONENT ACCESS
Vesta Gas and Electric Slide-In Range
n
3-5
. From behind the range, remove the access cover.
4. Locate the spark module at the back of the range.
. Remove the spark igniter wire connection from the spark
module.
Removing the Spark Module
1. From behind the range, remove the upper and lower
access covers.
2. Locate the Spark Module and remove all electrical
connections.
. Remove 2 spark module mounting screws.
Removing the Oven Sensor
1. From behind the range, remove the upper access cover.
2. Locate the oven sensor (SEE FIGURE 14) and remove the
2 wire disconnect plug.
. Remove 2 sensor mounting screws.
4. Pull the oven sensor out the back of the oven
e o ing the Direct S ar Ignition
board
1. From behind the range, remove the upper and lower
access covers.
2. Locate the DSI board (SEE FIGURE 14) and remove all
electrical connections.
. Remove 1 screw from the DSI mounting bracket.
4. Lift the DSI board up to clear the feet from the mounting
panel.
Removing the Gas Regulator/Safety
Valve
1. Disconnect the electrical supply to the range.
2. Turn o the gas supply to the range.
. Pull the range out of the installation and away from the
anti-tip bracket.
4. Disconnect the 2 quick disconnect plugs from the
regulator
5. Disconnect the house gas supply line from the regulator.
6. Disconnect the two remaining gas tubes from the
regulator (Broil and Cooktop gas tubes)
. Remove the mounting screws from the regulator
mounting bracket.
. Lower the regulator to release the bake burner tube from
the bake orifice.
9. During re-assembly make sure the pressure regulator bake
orifice is inserted into the bake burner tube.
Figure 13
Figure 14
Figure 15