ActiveScale™ P100 Support Guide
61
h. Repeat the previous steps to attach the other rail to the rack.
2. Replace the System Node. For more information, refer to
3.4.3 Replacing Storage Node 1U mounting kits
Table 3-22. Storage Node 1U mounting kit replacement overview
3.4.3.1 Removing a Storage Node 1U mounting kit
To remove a Storage Node 1U mounting kit, do the following:
1. Remove the Storage Node from the rails. For more information, refer to
2. From the rear of the rack, press the tab marked PUSH located on the inside of the 1U rail.
3. Free the mounting kit rail from the rack vertical rail.
4. Move to the front of the rack and grasp the 1U mounting kit rail.
5. Press the front tab marked PUSH to release the mounting kit rail.
Caution:
Make sure to hold the 1U bracket firmly and do not let go until it has
completely cleared the rack. There is a danger of dropping the bracket and losing
it in the interior of the rack, causing damage to the system, oneself, or others.
6. Complete the previous steps to remove the second 1U rail.
3.4.3.2 Installing a Storage Node 1U mounting kit
To install the replacement Storage Node 1U mounting kit, do the following:
Required Tools
Personnel Required
Replacement Time
None
2
3-4 hours
Summary of Contents for ActiveScale P100
Page 103: ...ActiveScale P100 Support Guide 101...
Page 104: ...ActiveScale P100 Support Guide 102...
Page 120: ...ActiveScale P100 Support Guide 118...
Page 124: ...ActiveScale P100 Support Guide 122...
Page 131: ...ActiveScale P100 Support Guide 129...
Page 132: ...ActiveScale P100 Support Guide 130...