GEAR MOTOR ASSEMBLY
Function
Turns the auger in the evaporator assembly.
Specifications
115-120V 60Hz or 230V 50Hz 2.5 RPM .13 HP
Check Procedure
MOTOR WILL NOT RUN.
1. Verify line voltage is present at the gear motor electrical
connector (wires 80 & 81).
2. Disconnect electrical connector and check for
resistance between line 1 and line 2. If resistance is
measured go to next step.
A. Remove gear motor electrical cover, inspect
terminal block and check wire resistance.
B. Disconnect and test capacitor.
C. Jumper capacitor wires and retest gearmotor for
resistance.
D. Replace gear motor assembly
3. If the gear motor trips on overload immediately or
intermittently:
A. Premix 11 ounces of cleaner with 6 ounces of water
in a non metallic container.
B. Add the entire solution to the evaporator and allow
to soak for a minimum of 4 hours.
C. Test run and check operation. If the issue is not
resolved, proceed with the next step.
4. Disconnect evaporator from gear motor assembly and
test run the gear motor. Replace gearmotor assembly
or refer to evaporator diagnostics.