16
CONNECTIONS
See “Product Delivery Location” on page 11
Drain
See “Drain Connections” on page 13
Rear of the Unit
Drain OUT
(11/2 NPS Male)
PVC Drain with
Air Gap
4” PVC coupling to minimum 1 1/2 “ PVC or Flexible drain line
connected to the 1 1/2” NPS drain funnel with service loop.
Drain lines must have a 1.5 inch drop per 5 feet of run (2.5
cm per meter), and must not create traps.
IIportant
Always and wire plumb to local, state and national codes.
Water Connection
See “Supply Connections” on page 13
Plain Water IN
Quick Connect
PN: WBL-96-087
Rear of the Unit
Use the supplied male quick connect (PN: WBL-96-087) and
6’ (1.8 m) of 3/8”beverage tubing to the plain water inlet on
the rear of the unit for the water supply connection.
IIportant
Water supply line needs to have an accessible water
shutoff valve..
IIportant
Leave enough slack in the water and drain lines to allow
access to the rear of the machine without disconnecting
the lines.
Check regulator and set water pressure.
IIportant
Regulators are factory set but will need to be checked
and possibly adjusted under flowing conditions once
the unit is operational.
Electrical
• Dedicated 120V 20 Amp Circuit
• Non GFI Outlet that accepts NEMA5 – 20 plug
• Outlet within 3’ (92 cm) of machine
• Supplied cord length 78” (198 cm)
If all electrical and grounding requirements have been
followed proceed to insert electrical plug from Fresh Blends
unit into wall receptacle.
Turn power switch, on the front top right of the unit, to the
ON position.
Front of Unit
Power
Switch