The location selected for the FreshBlender Beverage System
must meet the following criteria.
• The air temperature must be at least 40°F (4°C), but
must not exceed 90°F (32°C), climate class 4.
• The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
• Plain Inlet Water Temperature:
min/max = 40°F / 90°F (4°C / 32°C).
• Always use the water supply line supplied when
installing this appliance. Never reuse an old supply line.
• Verify floor of install location is level front to back, side
to side.
• Keep equipment area clear of combustible material.
Cletotaces
Top
18" (46 cm)
Sides
0" (0 cm)
Back
6" (15 cm)
Front
24" (61 cm)
n
Wtoaiag
Do not obstruct machine vents or openings.
Hetr pf Rejecripa
Mpdel
SysreI BTU
FB081TF
2300 BTU/hr (average)