Part Number REV00 04/08/2020 43
ICE MACHINE ELECTRICAL FLOWCHART
Power to ice
machine
Is BIC- Bin Level (LED)
and toggle SW closed
Is Low pressure
SW Closed
Is Chute Safety
SW closed
Is Low Float SW
Closed
Start Gear Motor
and 11
sec.
rota
ti
onal delay
Is 11 Sec delay
complete
Start compressor
and monitor
ro
tatio
n
R
otatio
n
stopped
Stop Compressor
and Gear motor.
Begin 15 min delay.
If 8 consecu
ti
ve
cycles = o
ff
yes
yes
yes
yes
yes
Has there been a
main power interrupt
to ice machine
Begin 15 minute
Power interrupt
delay. (Pwr.
Interrupt
Low Pressure SW
open
Low Water Float
SW open
Chute Safety SW
open
Stop Compressor
and Gear motor.
Begin 15 min delay
Stop Compressor
and Gear motor.
Begin 15 min delay
Stop Compressor
and Gear motor.
Begin 15 min delay
Monitor for the “fault” condi
ti
ons
during Ice making. Start 3 minute
ti
mer for “Min. Run
ti
me”
Check Inputs
no
no
no
no
no
yes
yes
yes
yes
yes
no
no
no
no
Is BIC- Bin Level (LED) or
toggle SW open in
Ice Making
Is 3 minute
ti
me
delay complete
Ice making
Stop Gear motor
and Compressor
yes
yes
8 minute “o
ff
ti
me”
delay following Ice
making
Is 8 minute
ti
me
delay complete
yes
no
no
no
Con
ti
nue to make
ice. Check “fault”
condi
ti
ons
no