Part Number REV00 04/08/2020 39
BLENDER CONTROLS FLOWCHART (CONTINUED)
Check +24 VDC input
voltage at J1 of Le
Blender/Mixer
board.
Is between
22 and 26 VDC?
Check high voltage
output between J11
and J12 of Smart
Relay Board (SRB).
Debug input power
circuitry between
power cord and
power supply.
Replace the power
supply.
Replace the
interconnecng
harness wiring
and/or connectors.
Is between
100 and 250
VAC?
Replace the
interconnecng
harness wiring
and/or connectors.
Check high voltage
input between J5 and
J6 of Le
Blender/Mixer
board.
Is between
100 and 250
VAC?
With Le Blender Door
"CLOSED", check status of
door sense input within
service mode on the user
interface.
Debug SRB and
input power
circuitry between
power cord and
Y
Y
N
N
N
Y
Y
N
N
Y
Does status
indicate
"CLOSED"?
Check Modbus
Communicaons cable
connecons at SRB J7
and Le Blender/Mixer
board J4.
Is between
22 and 26
VDC?
With Le Blender Door
"CLOSED", check voltage
between J9-Pin 1 and J9-
Pin 2 on the Le
Blender/Mixer board.
Is between
4 and 6 VDC?
With Le Blender Door
"OPEN", check voltage
between J9-Pin 1 and
J9-Pin 2 on the Le
Blender/Mixer board.
Is between
4 and 6 VDC?
With Le Blender Door
"CLOSED", check
voltage between J9-Pin
3 and J9-Pin 2 on the
Le Blender/Mixer
board.
With Le Blender Door
"OPEN", check status of
door sense input within
service mode on the
user interface.
Does status
indicate
"OPEN"?
Y
Y
Y
Y
N
N
N
Replace the le door
open/closed
magnec sensor or
le blender/mixer
Replace the le door
open/closed
magnec sensor or
le blender/mixer
With Le Blender Door
"OPEN", check voltage
between J9-Pin 3 and
J9-Pin 2 on the Le
Blender/Mixer board.
Check GREEN LED on
the Le Blender/Mixer
Board.
Is the GREEN
LED
"BLINKING"?
Replace the le
blender/mixer board
and/or Modbus
communicaons cable.
N
N
Is between
22 and 26
VDC?
Y
Set SW1 Modbus
address on Le
Blender/Mixer board to
"0000".
Is cable
connected?
Replace the le
blender/mixer
board.
Check SW1 Modbus
address on Le
Blender/Mixer board.
N
Is SW1 address
set to "0000"?
Connect Modbus
Communicaons cable
at SRB J7 and Le
Blender/Mixer board J4.
Is the GREEN
LED
"BLINKING"?
Y
Check GREEN LED on
the Le Blender/Mixer
Board.
With Le Blender
carriage at "HOME"
posion or "HOME"
sensor switch
acvated, check
voltage between J13-
Pins 1 & 2 on Le
Blender/Mixer board.
Is between
4 and 6 VDC?
With Le Blender
carriage not at "HOME"
posion and "HOME"
sensor switch not
acvated, check
voltage between J13-
Pins 1 & 2 on Le
Blender/Mixer board.
Is between
4 and 6 VDC?
Replace "HOME"
sensor switch
and/or
Blender/Mixer
N
N
Y
Y
With Le Blender Door
"CLOSED", check status
of the UL safety relay
coil.
Is the relay
coil
energized?
Replace the le
redundant door
open/closed
magnec sensor or
With Le Blender Door
"OPEN", check status of
the UL safety relay coil.
N
Is the relay
coil
energized?
Y
Y
N
With Le Blender Door
"CLOSED", select and turn
"ON" the "LEFT BLADE"
from the "OUTPUTS" screen
in the Service menu.
Is the "LEFT
BLADE" Motor
"ON"?
in the Service menu.
Is the "LEFT
BLADE" Motor
"OFF"?
Check high voltage
output between J2 and
J7 of Le Blender/Mixer
board.
Is between
60 and 250
VAC?
Check high voltage
between J2 of Le
Blender/Mixer board and
Pin 7 of the Le Safety
Door Relay.
Is between
60 and 250
VAC?
Y
N
Check high voltage
between J2 of Le
Blender/Mixer board
and Pin 4 of the Le
Safety Door Relay.
Is between
60 and 250
VAC?
Replace the Le Safety
Door Relay.
Replace the harness
between J2/J7 of the
Le Blender/Mixer
board and the Le
Check high voltage
between the power
input tabs of the "LEFT
BLADE" motor used for
blending the drink.
Is between
60 and 250
VAC?
Replace the "LEFT
BLADE" Motor and/or
Thermal Coutout.
Replace the Filter
Harness between the
Safety Door Relay and
the "LEFT BLADE"
N
N
N
N
Y
Y
Y
Y
Check high voltage
output between J2 and
J7 of Le Blender/Mixer
board.
Is between
60 and 250
VAC?
Check high voltage
between J2 of Le
Blender/Mixer board
and Pin 7 of the Le
Safety Door Relay.
Is between
60 and 250
VAC?
Check high voltage
between J2 of Le
Blender/Mixer board
and Pin 4 of the Le
Safety Door Relay.
Is between
60 and 250
VAC?
Y
N
Y
Y
N
N
With Le Blender Door
"CLOSED", select and turn
"ON" the "LEFT RINSE
SOLENOID" from the
"OUTPUTS" screen in the
Service menu.
Is "LEFT RINSE
SOLENOID"
"ON"?
Is "LEFT RINSE
SOLENOID"
"OFF"?
With Le Blender Door
"CLOSED", select and turn
"OFF" the "LEFT RINSE
SOLENOID" from the
"OUTPUTS" screen in the
Service menu.
Check voltage output
between J12 Pin 1 and
J12 Pin 2 of Le
Blender/Mixer board.
N
N
Y
Y
Is between
22 and 26
VDC?
Replace the le
blender/mixer
board.
N
Y
Check voltage output
between J12 Pin 2 of
Le Blender/Mixer
board and Pin 9 of the
Le Safety Door Relay.
Is between
22 and 26
VDC?
Check voltage output
between J12 Pin 2 of
Le Blender/Mixer
board and Pin 6 of the
Le Safety Door Relay.
Replace the harness
between J12 of the Le
Blender/Mixer board
and the Le Safety
Replace the Le Safety
Door Relay.
Is between
22 and 26
VDC?
Is between
22 and 26
VDC?
Check voltage output
between J12 Pin 1 and
J12 Pin 2 of Le
Blender/Mixer board.
Check voltage output
between J12 Pin 2 of
Le Blender/Mixer
board and Pin 9 of the
Le Safety Door Relay.
Is between
22 and 26
VDC?
Check voltage output
between J12 Pin 2 of
Le Blender/Mixer
board and Pin 6 of the
Le Safety Door Relay.
Is between
22 and 26
VDC?
Y
Y
Y
N
N
N
N
N
Y
Y
Check voltage at input
terminals of Le Rinse
Water Solenoid Valve.
Is between
22 and 26
VDC?
Check voltage at input
terminals of Le Rinse
Water Solenoid Valve.
Is between
22 and 26
VDC?
Replace the harness
between the Le
Safety Door Relay and
the Le Rinse Water
Y
N
N
Y
Replace the Le Rinse
Water Solenoid Valve.
N
Y
Y
Y
N
N
N
N
Y
Y
With Le Blender Door
"CLOSED", select and turn
"ON" the "LEFT BLEND
SLIDE" from the "OUTPUTS"
screen in the Service menu.
Did "LEFT BLEND
SLIDE" go to
opposite posion
limit?
Check to ensure stepper
motor harness plug is
connected to J10
receptacle on the Le
Blender/Mixer Board.
N
N
Y
Y
Is it
connected?
OK
N
Y
Connect the stepper
motor harness plug to
J10 receptacle on the
Le Blender/Mixer
Board.
Replace the Stepper
Motor Harness and/or
Le Blender/Mixer
Board..
N
With Le Blender Door
"CLOSED", select and turn
"OFF" the "LEFT BLEND
SLIDE" from the "OUTPUTS"
screen in the Service menu.
Did "LEFT BLEND
SLIDE" return to
inial posion
limit?
With Le Blender Door
"CLOSED", select and turn
"ON" the "LEFT BLEND
SLIDE" from the "OUTPUTS"
screen in the Service menu.
Did "LEFT BLEND
SLIDE" go to
opposite posion
limit?
N
Y
Y
With Le Blender Door
"CLOSED", select and turn
"OFF" the "LEFT BLEND
SLIDE" from the "OUTPUTS"
screen in the Service menu.
Did "LEFT BLEND
SLIDE" return to
inial posion
limit?
-
-
Check high
voltage input
line at J1 of
Power Supply.
Is between
100 and 250
VAC?
Check +24 VDC
output at J2 of
Power Supply.
Is between
22 and 26 VDC?
Power Supply
High Voltage Input
Modbus Communicaons
Magnec Door Sensor Blender Control
Magnec Door Sensor
Motor Relay Control Enable
Home Sensor Switch
UL (Redundant) Safety Relay
Blend Motor Control
Rinse Solenoid Valve Control
Stepper Motor Slide Control
Summary of Contents for FB081TF
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 24: ...24 Part Number REV00 04 08 2020 Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 88: ...88 Part Number REV00 04 08 2020 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ......
Page 94: ......
Page 95: ......