Actual space requirements
Far more room than the specified minimum space requirement is needed in front of the appliances to
operate the combi ovens safely, in particular to handle hot food safely.
Larger wall gaps are generally recommended to provide access for servicing.
In the installation location, the following parts must not be covered, obstructed or blocked (see also
'Design and function of the combi oven'):
■
Air vent on the top of the appliance
■
Ventilation port on the top of the appliance
■
Ventilation slots on the rear of the appliance
■
Gap on the front of the appliance between the feet (for 6.06/6.10/10.10 mini)
■
Ventilation slots in the appliance floor (for 6.10 mini 2in1)
Minimum space required - width and depth
The following diagram and table show the space required for the appliance for different installation and
operating situations. They also show the minimum horizontal distances from adjacent walls and surfa‐
ces:
a
c
b
180°
c
B‘
90°
T
B
Di‐
men‐
sion
Meaning
Space re‐
quired
6.06 mini
6.10 mini
10.10 mini 6.10 mini
2in1
B
Width requirement, appliance
door open at 90°
[mm]
633
633
633
633
B'
Width requirement, appliance
door open at 180°
[mm]
1055
1055
1055
1055
T
Depth requirement when
opening the appliance door
[mm]
1137
1315
1315
1339
a
Safety clearance on left-hand
side
[mm]
50
50
50
50
b
Safety clearance at rear
[mm]
50
50
50
50
c
Safety clearance on right-
hand side
[mm]
50
50
50
50
5 Setting up the appliance
Installation manual
46
Summary of Contents for Convotherm OES mini easyTouch
Page 1: ...Combi oven Read instructions before use OES mini easyTouch Installation manual Original ENG ...
Page 2: ......
Page 105: ......