6.1.3 Carrying out the electrical installation
Requirements
Check that the following requirement has been met:
■
The connection point of the appliance is disconnected from the customer power supply and protec‐
tive measures taken to ensure the power cannot be switched on again.
Checking the supply ratings and electrical connections
Follow the steps below to check the connection to the installation system and the electrical connec‐
tions:
Step
Action
Illustration
1
Remove the rear panel from the appliance.
The circuit diagram and spare parts list are located in
the wiring compartment.
2
Check that the electrical supply ratings on the type plate
match the figures for the installation system and those
given in the circuit diagram. It is only permitted to con‐
nect the combi oven if all these values tally with each
other.
3
Check all screw connections and terminals on the appli‐
ance. The connections may have worked loose during
transport.
Carrying out the electrical installation
Follow the steps below to connect your appliance to the electrical supply:
Step
Action
Illustration
1
Connect the appliance at the designated connection
point (1) to an equipotential bonding system.
1
3
2
2
Use the mains power cord to connect the power supply
to the appliance at the -X10 terminal strip (2).
3
Make sure that the cable gland (3) is tightened firmly
because it also acts as a cable strain relief.
4
Reset the thermal cutout if necessary.
5
Fit the rear panel on the appliance and check that it is
fixed correctly in place.